Products


Preview

Preview

Preview

Preview




Photoelectric Isolated RS-232 to RS-485/422 Converter
Manufacturer Part Number: HESC-T-028
Brand: Predision
$ 139.00
- Working Temperature: -40 ~ 85°C
- ±15 KV ESD Protection for RS-232 Interface, 600W Lightning Surge Protection for Each Wire of RS-485/422 Interface
- Isolation Voltage: 2,500 Vrms 500 VDC Continuous
- Baud Rate: 300 ~ 115,200 bps
See our Shipping Policy for delivery regions and fees
HESC-T-028 is an industrial converter with photoelectric isolation. It complies with RS-232C, RS-485 and RS-422 standards and converts single-ended RS-232 signal to balanced differential RS-485 or RS-422 signals. The built-in photoelectric isolator can provide as high as 2,500 Vrms isolated voltage. The fast transient voltage suppression is designed to protect RS-485/RS-422 interface. This device adopts advanced TVS (TRANSIENT VOLTAGE SUPPRESSOR).
The converter has zero-delay automatic transceiver conversion. The unique I/O circuit automatically controls the data flow direction without any handshake signals (such as RTS, DTR, etc.). There is no need of jumper wire setting for implementing full-duplex (RS-422) and half-duplex (RS-485) mode. All these functions ensure HESC-T-028 to be suitable for all existing communication software and interface hardware, without the need for any software modifications to the previous RS-232-based working method.
HESC-T-028 serial converter can provide reliable connections for point-to-point and point-to-multipoint communications. At point-to-multipoint mode, the converter supports the connection with 128 RS-485 or RS-422 interface devices, with a data communication rate of 300 to 115,200 bps.
The converter has zero-delay automatic transceiver conversion. The unique I/O circuit automatically controls the data flow direction without any handshake signals (such as RTS, DTR, etc.). There is no need of jumper wire setting for implementing full-duplex (RS-422) and half-duplex (RS-485) mode. All these functions ensure HESC-T-028 to be suitable for all existing communication software and interface hardware, without the need for any software modifications to the previous RS-232-based working method.
HESC-T-028 serial converter can provide reliable connections for point-to-point and point-to-multipoint communications. At point-to-multipoint mode, the converter supports the connection with 128 RS-485 or RS-422 interface devices, with a data communication rate of 300 to 115,200 bps.
| Standards | EIA/TIA RS-232C/ RS-485 /RS-422 |
| Connector | DB9 Female Connector for RS-232 Interface Input and 10-pin Terminal Block for RS-485/RS-422 Interface Output |
| Protect Level | ±15KV ESD Protection for RS-232 Interface and 600W Lightning Surge Protection for Each Wire of RS-485/422 Interface |
| Isolation | Isolated Voltage 2,500 Vrms 500 VDC Continuous |
| Working Mode | Asynchronous Half-duplex or Full-duplex |
| Signal Indicators | Power (PWR), Transmit (TXD), Receive (RXD) |
| Transmission Media | Twisted-pair or Shielded Cable |
| Baud Rate | 115.2 Kbps to 300m, 38.4 Kbps to 2.4Km, 9,600 bps to 5 Km |
| Dimension | 117 ×80 ×25 mm |
| Operating Temperature | -40°C to 85°C |
| Relative Humidity | 5% to 95% (Non-condensing) |
| Transmission Distance | 0 - 5,000m (115.2 Kbps - 9,600 bps) |
Mini RS-232 to RS-485/422 Converter, Plastic, with 5-pin Terminal Block, Mini size, Automatic Traffic Direction Control, No Need External Flow Control Signal (RTS), Power: Port-powered, No Need External Power, Connected & Serial Port Initialization, Real TXD/RXD/GND Communication, Transmission Distance: 1,200m, Baud rate: 300 bps-115.2 Kbps, Operating Temperature: -25℃ to 70℃, Supports All Operating Systems
RS-232 to RS-485/422 Converter, Plastic with Terminals, Baud Rate: 300 bps - 115,200 bps, Working Temperature: -40℃ to 85℃, Transmission Distance: 1,200m (RS-485/422); 5m (RS-232), Protection: Lightning Surge Protection 2KA
RS-232 to RS-485/422 Port-powered Converter with Photoelectric Isolation, Aluminum Enclosure, Wall Mounted, Baud Rate: 300 bps - 115.2 Kbps, Operating Temperature: -25℃ to 70℃
RS-232 to RS-485/422 Port-powered Converter with Photoelectric Isolation, Plastic with Terminals, ±15KV ESD Protection for RS-232, 600W Lighting and Surge for Each Wire of RS-485/422, Isolation: 2500 Vrms Isolated Voltage, Continuous 500 VDC, Baud Rate: 300 bps - 115.2 Kbps, Working Temperature: -40℃ to 85℃
Industrial RS-232 to RS-485/422 Port-powered Converter with photoelectric Isolation, ±15KV ESD Protection for RS-232, 600W Lighting and Surge for Each Wire of RS-485/422, Isolation: 2500 Vrms 500 VDC, Baud Rate: 300-115.2 Kbps, Working Temperature: -40℃ to 85℃, Transmission Distance: 0 - 1,200m (115,200 bps - 9,600 bps)
RS-232 to RS-485/422 Converter, Wall Mounted, 600W Lighting and Surge Protection for Each Wire of RS-485/422, Transmission Distance: 115.2 Kbps to 300m, 38.4 Kbps to 600m, 9,600 bps to 1.2Km, Working Temperature: -25℃ to 70℃
RS-232 to RS-485/422 Photoelectric Isolated Converter, 600W Lighting and Surge Protection for Each Wire of RS-485/422, Isolation Degree: Isolated Voltage 2,500 Vrms 500 VDC Continuous, Baud Rate: 300 bps-115.2 Kbps, Working Temperature: -25℃ to 70℃, Transmission Distance: 0-1,200m
Industrial RS-232 to RS-485/422 Photoelectric Isolated Converter, Baud Rate: 300 bps - 115.2 Kbps, Supports to Connect 128 RS-485 or RS-422 Devices, Transmission Distance: 5,000m (9,600 bps), 2,500 Vrms/500 VDC Enhanced Isolation, Special DC/DC Module, 600W Lighting and Surge Protection for Each Wire of RS-485/422, Working Temperature: -40℃ to 85℃
Industrial RS-232 to RS-485/422 Converter with Photoelectric Isolation, Wall Mounted, Baud Rate: 300 bps-115.2 Kbps, Supports to Connect 128 RS-485 or RS-422 Devices, Transmission Distance: 5,000m (9,600 bps), 2,500 Vrms/500 VDC Enhanced Isolation, Special DC/DC Module, ±15KV ESD Protection for RS-232, 1,500W Lighting and Surge Protection for Each Wire of RS-485/422, Working Temperature: -40℃ to 85℃
RS-232 to RS-485/422 Photoelectric Isolated Converter with Surge Protection, Wall Mounted, 600W Lighting and Surge for Each Wire of RS-485/422, Isolation: Isolated Voltage 2,500 Vrms 500 VDC Continuous, Baud Rate: 115.2 Kbps to 300m, 38.4 Kbps to 600m, 600 bps to 1.2km. Operating Temperature: -25 ~ 70℃, Transmission Distance: 0 - 1,200m
Industrial RS-232 to RS-485/422 Converter with Photoelectric Isolation, Active Screw, Port Protection: RS-232 ±15KV ESD Protection, RS-422/485 Each Wire 600W Surge, Isolation: Isolated Voltage 2,500 Vrms or 500VDC Continuous, LEDs for Indicating PWR TXD, and RXD Activity, Baud Rate: 115.2 Kbps to 300m, 38.4 Kbps to 2.4Km, 9,600 bps to 5km, Operating Temperature: -40℃ to 85℃, Transmission Distance: 0 - 5,000m(115.2 Kbps-9,600 bps)
5-Year Warranty
24/7 Live Service
Global Support
Partner Privileges
OEM/ODM Available
Company Information
Contact Us
Our Address
11 Commerce St.
Norwalk, CT 06850
United States
Sign up for Our Newsletter
Career Opportunities
We make every effort to create a fair and productive workplace.
See our latest openings below!
Information & News
Shop With Confidence
Shop with the top ranking
payment platform
We accept Visa, Mastercard, American Express, Paypal, Company Purchase Orders
We're Here to Help!
Contact us and we'll get you to the right person as soon as possible!








Copyright © 2013-2026 Predision LLC. All Rights Reserved
Predision LLC - Authorized distributor of Henrich Electronics industrial Ethernet & IoT connectivity solutions