RS-232/RS-485 to 4-port RS-485 Hub
Manufacturer Part Number: HESC-T-035
Brand: Predision
$ 335.00
- Working Temperature: -40 ~ 85°C
- Isolation: 2,500 Vrms 500 VDC Continuous Isolated
- ±15 KV ESD Protection for RS-232 Port, 600 W Lightening and Surge Protection for Each Wire for RS-485 Port
- Baud Rate: 300 bps ~ 115.2 Kbps
See our Shipping Policy for delivery regions and fees
HESC-T-035 is a hub specially designed for RS-485 Bus under complicated electromagnetic field. The transmission rate for this hub is as high as 115.2 Kbps. To ensure the safety and reliability of the data communication, RS-485 port adopts photoelectric isolation technology to prevent from lightning and surge. The built-in photoelectric isolator and 600W surge protection circuit can provide 2,500V isolated voltage for lightning and ESD protection. Meanwhile, it adopts external switch power, preventing from common ground interference. For all these protections, this converter is quite good for outdoor application.
Under RS-485 working mode, the distinguished circuit can automatically identify the direction of data flow, and switch it automatically, so as to control the circuit, and solve RS-485 time delay problem. The transmission distance of RS-485 port is more than 1,200m. This model is widely used in highway toll system, road monitoring system, and power system.
HESC-T-035 RS-485 hub supports star RS-485 Bus connection. Each port supports short-circuit, open-circuit protection, and 2,500V photoelectric isolation. User can easily change the structure of RS-485 Bus, divide the network segment, and improve the communication reliability. When the device breaks down, the network segment with problem will be isolated, so as to ensure other network segment to work smoothly. This performance greatly improve the reliability of RS-485, and shorten the maintenance time of the network.
Under RS-485 working mode, the distinguished circuit can automatically identify the direction of data flow, and switch it automatically, so as to control the circuit, and solve RS-485 time delay problem. The transmission distance of RS-485 port is more than 1,200m. This model is widely used in highway toll system, road monitoring system, and power system.
HESC-T-035 RS-485 hub supports star RS-485 Bus connection. Each port supports short-circuit, open-circuit protection, and 2,500V photoelectric isolation. User can easily change the structure of RS-485 Bus, divide the network segment, and improve the communication reliability. When the device breaks down, the network segment with problem will be isolated, so as to ensure other network segment to work smoothly. This performance greatly improve the reliability of RS-485, and shorten the maintenance time of the network.
| Standards | RS-232C, RS-485 EIA/TIA |
| Interface | RS-232C: 10-pin Terminal Block RS-485: 10-pin Terminal Block |
| Transmission Media | Twisted-pair or Shielded Cable |
| Working Mode | Asynchronous Half-duplex |
| Operating Power | 9-30 VDC/150 mA |
| Isolated Voltage | 2,500 Vrms 500 VDC Continuous, DC/DC Module |
| Baud Rate | 300 bps-115.2 Kbps |
| Protection Level | RS-232: ±15 KV ESD Protection RS-485: 600 W Lightening and Surge Protection for Each Wire |
| Transmission Distance | 0-5,000m (115.2 Kbps-300 bps) |
| Dimension | 120 × 80 × 25 mm |
| Operating Environment | -40℃ to 85℃, Relative Humidity 5% to 95% |
Industrial RS-232 to 2-port RS-485 Converter with Optical Isolation, Automatic Traffic Direction Control, No Need External Flow Control Signal (RTS), Real TXD/RXD/GND Communication, Baud Rate: 300 bps - 115.2 Kbps, Allows Connecting 128 RS-485 or RS-422 Devices, Transmission Distance: 5,000m (9,600 bps), Power: 9 - 30 VDC/350 mA, Power & Data Flow Indicator, Failure Detection, 2,500 Vrms/500 VDC Enhanced Isolation, Special DC/DC Module, RS-485/422 Provides Each Wire with 600W Lighting, Surge & ±15KV ESD Protection, Operating Temperature: -40℃ to 85℃, Works with All Communication Software, Plug & Play, Supports All Operating System
DIN-rail Industrial RS-232/485 to 2-port RS-485 Hub, Operating Power: 9-30 VDC / 150 mA, Isolation: 2,500 Vrms 500 VDC Continuous Isolated Voltage, DC/DC Module, Baud Rate: 300 bps - 115.2 Kbps, ±15KV ESD Protection for RS-232, 600W Lighting and Surge Protection for Each Wire of RS-485, Transmission Distance: 0-5,000m (115,200-300 bps), Working Temperature -40℃ to 85℃
RS-232/RS-485 to 4-port RS-485 Hub (Din-rail), Optical Isolated, Operating Power: 9-30 VDC/150 mA, LEDs for Indicating PWR TXD, RXD, and E1-E4 Activity, Isolated Voltage 2500 Vrms 500 VDC Continuous, DC/DC Module, Baud rate: 300 bps-115.2 Kbps, Protection level: RS-232 ±15KV ESD Protection, RS-485 Provides Each Wire with 600W Lightning, Surge Protection, Transmission Distance: 0-5,000m (115.2 Kbps-300 bps), Operating Temperature: -40℃ to 85℃, Work with all Communication Software, Plug & play
Industrial RS-485/422 to 4-port RS-485/422 Hub, 2,500 Vrms 500 VDC Continuous Isolated Voltage, DC/DC Isolated Module, Baud Rate: 300 bps - 115.2 Kbps, Operating Voltage: DC 9-48V, 8/20μs 3,000A Lightning Surge Protection for RS-485/422 Each Wire, Transmission Distance: 0 - 1,200m (115,200-300 bps), Operating Temperature: -40℃ to 85℃
RS-232/485 to 4-port RS-485/422 photoelectric Isolated Hub, Isolated Voltage 2,500 Vrms 500 VDC, DC/DC Isolated Module, Baud Rate: 300 bps - 115.2 Kbps, Operating Voltage: DC 9-48V/AC 220V, 8/20μs 3,000A Lightning Surge Protection for RS-485/422 Each Wire, Transmission Distance: 0 - 1,200m (115,200 - 300 bps), Working Temperature: -40℃ to 85℃
RS-232/RS-485 to 8-port RS-485 Photoelectric Isolated Hub, Din-rail, Plastic, Voltage Input: DC 12-48V 350 mA, Isolation: Isolated Voltage 2,500 Vrms 500 VDC Continuous, DC/DC Isolated Module, Transmission Rate: 300 bps - 115.2 Kbps, 15KV ESD Protection for RS-232 Ports, 1,500W Lightning and Surge Protection for Each Wire of RS-485 Ports, 2,000V Lightning and Surge Protection for Power Supply, Transmission Distance: 0-1.2km (115,200 - 300 bps), Working Temperature -40℃ to +85℃
Industrial RS-232/RS-485 to 8-port RS-485 Hub, Baud Rate: 300 bps - 115.2 Kbps, Each RS-485 Port Can Connect with 128 Devices, Transmission Distance: 5,000m (9,600 bps), 2,500 Vrms 500 VDC Continuous Isolated Voltage, DC/DC Isolated Module, ±15 KV ESD Protection for RS-232, 1,500W Lighting and Surge Protection for Each Wire of RS-485, Working Temperature: -40℃ to 85℃
Industrial Rack-mount RS-232/RS-485 to 8-port Photoelectric Isolated RS-485 Hub,1U Enclosure, AC 100-240V 50/60Hz, 2,500 Vrms 500 VDC Continuous Isolated Voltage, DC/DC Isolated Module, Baud Rate: 300 - 115.2 Kbps, ±15KV ESD Protection for RS-232, 1,500W Lighting and Surge Protection for Each Wire of RS-485, Transmission Distance: 0-5KM (115,200 - 300 bps), Working Temperature -40℃ to 85℃
RS-232/RS-485 to 8-port RS-485 Photoelectric Isolated Serial Hub, AC/DC Dual Power Supply, 2,500 Vrms 500 VDC Continuous Isolated Voltage, DC/DC Isolated Module, Transmission Rate: 300 bps - 115.2 Kbps, ±15 KV ESD Protection for RS-232, 1,500W Lighting and Surge Protection for Each Wire of RS-485, Transmission Distance: 0 - 5km (115,200 - 300 bps), Working Temperature: -40℃ to 85℃
RS-232/RS-485 to 16-port RS-485 Hub, Optical Isolated, 1U Enclosure, Operating Power: AC 100 ~ 240V 50/60 Hz, Transmission Rate:300 bps - 115.2 Kbps
5-Year Warranty
24/7 Live Service
Global Support
Partner Privileges
OEM/ODM Available
Company Information
Contact Us
Our Address
11 Commerce St.
Norwalk, CT 06850
United States
Sign up for Our Newsletter
Career Opportunities
We make every effort to create a fair and productive workplace.
See our latest openings below!
Information & News
Shop With Confidence
Shop with the top ranking
payment platform
We accept Visa, Mastercard, American Express, Paypal, Company Purchase Orders
We're Here to Help!
Contact us and we'll get you to the right person as soon as possible!








Copyright © 2013-2026 Predision LLC. All Rights Reserved
Predision LLC - Authorized distributor of Henrich Electronics industrial Ethernet & IoT connectivity solutions